ROUTING SWITCHER PROCESSORHDS-X580033 INPUT BOARD SETHKS-5810MHKS-5810SD34 CASCADE INPUT BOARD SETHKS-5811MHKS-5811SD33 INPUT DISTRIBUTION BOARDHKS-58
1-2 (E)HDS-X58001-2. Operating EnvironmentwDo not install the unit in a place subject to excessive oilvapor, steam, moisture, or dust, otherwise a fir
1-3 (E)HDS-X58001-4. Installation Spacem. The rear side of the unit should be at least 40 cm (16 inches) away from walls for ventilation andmaintenanc
1-4 (E)HDS-X58001-5. Rack MountingThe HDS-X5800 is mounted in the 19-inch standard rack.To mount the HDS-X5800 in the rack, use the rack mountkit that
1-5 (E)HDS-X58001-5-2. Rack Mounting ProcedureThis section describes the rack mounting procedure usingthe rack mount kit supplied with the HDS-X5800.n
1-6 (E)HDS-X58006. Fix the rack angle in the rack using the specified eightscrews.RackB5 x 12B5 x 12Rack angleRack angle1-5. Rack Mounting
1-7 (E)HDS-X58001-6. Installation of Optional BoardsmThe usable optional boards are different depending on the type of signal to handle.. The HKS-58xx
1-8 (E)HDS-X58001-6-3.Installation/Removal of Plug-in BoardscBefore installing or removing the boards, be sure to turnoff the power switches and disco
1-9 (E)HDS-X5800Removal1. Open the eject levers of the board in the direction ofarrow B.2. Remove the board from the HDS-X5800.nRemove the board while
1-10 (E)HDS-X58001-6-4. Installation/Removal of ConnectorBoardscBefore installing or removing the boards, be sure to turnoff the power switches and di
1-11 (E)HDS-X5800RemovalRemove them by reversing the installation procedure.HKS-5811M/5811SD (CI-29 Board)The HKS-5811M/5811SD consist of the two type
HDS-X5800! WARNINGThis manual is intended for qualified service personnel only.To reduce the risk of electric shock, fire or injury, do not perform an
1-12 (E)HDS-X58001-7. Matching Connectors and CablesTo connect the cable to the unit, use the following connectors and cables or their equivalents.Mod
1-13 (E)HDS-X58001-8. Input and Output Signals ofConnectorsThe input and output signals of the connectors at the rearpanel are as follows.REMOTE2 A/B
1-14 (E)HDS-X58001-9. System Connection1-9-1. S-BUS Data LinkThe routing switcher system is connected with the S-BUS data link using a 75 Z coaxial ca
1-15 (E)HDS-X5800The following diagram shows an example of the connection for the data link of the S-BUS when theHDS-X5800 is set as a primary station
1-16 (E)HDS-X5800Precautions for connection. For the routing switcher that is used as the primary station, set the S/P selector switch on the CPU boar
1-17 (E)HDS-X5800mThe usable optional boards are different depending on the type of signal to handle.. The HKS-58xxM is the optional board that suppor
1-18 (E)HDS-X58001-10-2. How to Configure Optional BoardsThe following examples of configuring the optional boards are possible to extend inputs and o
1-19 (E)HDS-X58001-10-3. Cascade Connection ExampleIn order to extend the input, the optional 34 cascade input board set (HKS-5811M or HKS-5811SD)shou
1-20 (E)HDS-X5800IN 1SDI OUT 1SDI OUT 2IN 1HKPF-SP003PFV-SP3300Input 1-264Output1-272Output273-544PFV-SP3300 (HKPF-SP003 17 pcs are installed) 15 unit
1-21 (E)HDS-X58001-10-5. Input/Output Extension ExampleIn order to extend both of the input and output, combination of the input extension and the out
HDS-X58001 (P)Attention-when the product is installed in Rack:(For HDS-X5800)1. Prevention against overloading of branch circuitWhen this product is i
1-22 (E)HDS-X58001-10-6. Control System Connection Example and SetupInput to 1024*2232 boards 264 boards 264 boards 264 boardsPFV-SP3300 distributorHK
1-23 (E)HDS-X58001-11. Setting the On-Board Switches and Description of LEDs1-11-1. CPU-339 Board (HDS-X5800)<LEDs>Status of the REMOTE 1 connec
1-24 (E)HDS-X5800Status of the entire systemRef. No. (Address) LED name Status when lights upD701 (G-8) ACTIVE Control is executed. (The CPU-339 board
1-25 (E)HDS-X5800<Switches>nThe two CPU-339 boards that are inserted in slots A and B, must have the exactly same setup.S701 (D-8) : Station ID/
1-26 (E)HDS-X5800OPEN12345678Factory setting( indicates the switch lever position.)S702 (E-8) : REMOTE 1 SELECT switch8-pin piano-type switchBIT1 t
1-27 (E)HDS-X5800OPEN12345678Factory setting( indicates the switch lever position.)BIT2 : Cross-level Tie Line function valid/invalidselector switc
1-28 (E)HDS-X5800BIT6 : Unit ID/IP setting method selector switchUsed to select the method of setting the IP address in thedata link that is connected
1-29 (E)HDS-X5800B : Cross-point testIt checks the signal transmission circuit and detec-tion circuit.Contents of this test are the same as those of t
1-30 (E)HDS-X5800Side A (Component side)D3051D3052D3053D3054D3055D3056D3057D3058D3059D3060D3061D3062D3063D3064D3065D3066D3067D3001D3002D3003D11D10D306
1-31 (E)HDS-X58001-11. Setting the On-Board Switches and Description of LEDsON12345678Factory setting( indicates the switch lever position.)BIT5 to
1-32 (E)HDS-X58001-11-3. MX-104 Board (HKS-5830SD)<LEDs>D10 (B-7) : +++++5 V LEDLights on when +5 V power supply is normal.D11 (B-7) : +++++4.1
1-33 (E)HDS-X58001-11-5. EQ-91 Board (HKS-5811M)<LEDs>D6007, D6008 (A-1) : +++++5 V-1, +++++5 V-2 LEDLights on when +5 V power supply is normal.
1-34 (E)HDS-X5800D521, D523, D524, D526 : REMOTE1 PRIMD521 : REMOTE1 AD523 : REMOTE1 BD524 : REMOTE1 CD526 : REMOTE1 DLights off : Working as a second
1-35 (E)HDS-X58001-11. Setting the On-Board Switches and Description of LEDsD535, D541, D548, D553 : REFERENCE 625D535 : REF AD541 : REF BD548 : REF C
1-36 (E)HDS-X58001-11. Setting the On-Board Switches and Description of LEDsD2 : DC +++++12 V BPower supply unit B system status indicationLights in g
1-37 (E)HDS-X5800D10 : REF BStatus indication of reference B systemLights in green when the reference video signal is normallyinput. Lights in red whe
1-38 (E)HDS-X58001-11-8. CNI-11 Board (HKS-5810M)<LED>D304 (D-1) : +++++3.3 V LEDLights on when +3.3 V power supply is normal.1-11-9. CNI-12 Boa
1-39 (E)HDS-X58001-11-11. CNI-14 Board (HKS-5810SD)<LED>D9004 (C-1) : +++++5.0 V LEDLights on when +5 V power supply is normal.1-11-12. CNO-13 B
1-40 (E)HDS-X5800Side A (Component side)D601ABC DE F GH J1234Side A (Component side)A12BCDEFD90041-11-14. CNO-15 Board (HKS-5860SD)<LED>D9004 (D
1-41 (E)HDS-X58001-11-17. RM-192 Board (HDS-X5800)<LED>D201 : +++++12 V LEDLights on when the +12 V power supplied from the power supply units A
1 (E)HDS-X5800Table of ContentsManual StructurePurpose of this manual ...
1-42 (E)HDS-X58001-12. Setting IP AddressThe method of setting IP address differs depending on the switch S703-6 (unit ID/IP setting methodselector sw
2-1 (E)HDS-X5800Section 2Service Overview2-1. Main Parts LocationFront sideA1A2B1B2CPU-339 boardsIF-844 boardsMX-103 board (HKS-5830M)MX-104 board (HK
2-2 (E)HDS-X5800Rear sideCNO-13 board(HKS-5860M)CNO-15 board(HKS-5860SD)CNO-14 board(HKS-5860M)CNO-16 board(HKS-5860SD)CI-29 board(HKS-5811M/HKS-5811S
2-3 (E)HDS-X5800Fan123456789!/!-!=![!]Fan units (Rear)Fan units (Top)Fan units (Bottom)DU-153 boardsDU-141 boardsDU-141 boardsFAN (TOP) 1 L1 (LEFT1)2
2-4 (E)HDS-X58002-2. Removing/Installing the Front PanelRemovalLoosen the four screws (with drop-safe), and then removethe front panel in the directio
2-5 (E)HDS-X58002-3. Error IndicationThis section describes errors that are indicated on the ERROR No. indicator on the CPU-339 board orindicated on t
2-6 (E)HDS-X58002-3-2. Front Panel Status Indication (LE-251/FP-129 Board)An approximate status such as occurrence or non-occurrence of error is indic
2-7 (E)HDS-X5800RemedyCheck that thePOWER switch of thepower supply unit isturned on. Check theconnection of thepower cable. Replacethe defective powe
2-8 (E)HDS-X5800LEDs on the FP-129 boardLEDs on the FP-129 board light on when the switch S106 (DISPLAY ON/OFF) is pressed.nThe display mode of the LE
2-9 (E)HDS-X5800Name of LEDFAN L1(TOP)L2C1C2R1R2FAN L1(BOTTOM)L2C1C2R1R2FAN 1(REAR)2Ref No.D514D516D518D520D522D525D528D531D534D537D540D543D545D547Con
2 (E)HDS-X58001-11. Setting the On-Board Switches and Description of LEDs ...1-23 (E)1-11-1. CPU-339 Board (HDS-X5800) ...
2-10 (E)HDS-X5800Name of LEDREFERENCE 525(REF A)6251125750PROGRESSIVERef. No.D533D535D536D538D527ContentsStatus ofREFERENCE AsystemStatusLights offThe
2-11 (E)HDS-X5800Name of LEDREFERENCE 525(REF C)6251125750PROGRESSIVERef. No.D546D548D549D550D530ContentsStatus ofREFERENCE CsystemStatusLights offThe
2-12 (E)HDS-X58002-4. Cleaning FilternIf dust adheres to the filter, the ventilation holes areblocked and airflow inside the machine is also blocked s
2-13 (E)HDS-X58002-6. Data BackupThe table data that are set from the personal computer (to be abbreviated as PC hereafter) are stored in theRAM on th
2-14 (E)HDS-X58002-6-2. Installing BZR-20The BZR-20 can be used in the IBM PC/AT compatible PC in which Windows 98/2000 is installed.Operating environ
2-15 (E)HDS-X58002-6-3. Uploading DataUpload the various setup data of the system equipment is executed from primary stations to a PC.1. Install the B
2-16 (E)HDS-X58002-6-4. Downloading DataDownloads the various setup data that are saved in a PC, to the system equipment through primarystation.1. Ins
HDS-X5800The material contained in this manual consists ofinformation that is the property of Sony Corporation.Sony Corporation expressly prohibits th
Printed in JapanSony Corporation 2002. 7 16B&P Company ©2001HDS-X5800 (SY) J, E3-206-225-03
3 (E)HDS-X5800Purpose of this manualThis manual is the installation manual of Routing Switcher Processor HDS-X5800and the optional boards.This manual
4 (E)HDS-X5800ContentsThe following is a summary of all the sections of this manual.Section 1 InstallationThis section describes the operating environ
1-1 (E)HDS-X5800Section 1Installation1-1. Installation ProcedureThe following chart shows the procedure for installing the unit.For details of the fol
Komentarze do niniejszej Instrukcji